Sito
segnalato su: |
|
|
|
|
|
|
richiedi
un
preventivo
di
dosimetri
 |
|
|
The GammaTest C is a light, robust battery
operated pocket-sized dose rate alarm unit for the personal radiation
protection for the detection of gamma and X-rays. Four different alarm
thresholds can be adjusted. When being exceeded, an optical (red LED) and
acoustic alarm will be triggered.
The dose rate alarm threshold 25 µSv/h is
required by the German Fire Brigades Regulation (FwDV 500) for the
determination of a danger zone. The alarm threshold 40 µSv/h is required in
the range of non destructive testing (NDT) during radiographic processing (for
example by X-rays): the local dose rate outside the control area may not
exceed 40 µSv/h.
The splash-proof, anodically treated aluminium
housing of the GammaTest C ensures a shielding against EMC influence.
|
 |
|
Technical Data |
| Detector: |
energy compensated Geiger-Müller tube |
| Measuring size: |
ambient dose equivalent rate H*(10) |
| Energy range: |
40 keV - 1,3 MeV |
| Alarm thresholds: |
25 µSv/h, 40 µSv/h, 1 mSv/h, 10 mSv/h |
| Overload capacity: |
> 500 mSv/h |
| Temperature range: |
-30 °C up to +60 °C (operation) -40 °C up to +70 °C
(storage) |
| Acoustic alarm: |
> 80 dB(A) measured at 30 cm distance |
| Dimensions / Weight: |
(106 x 67 x 23) mm, without clip / approx. 190 g (with
batteries) |
| Power supply: |
2x AAA (LR03) |
| Operating life: |
approx. 250 hours |
|
The GWL 10m is an accumulator operated dose
rate alarm unit, independent of mains supply, for the detection of gamma
radiation and X-rays. The instrument has four alarm thresholds, triggering
optical and acoustic alarm when being exceeded. The acoustic alarm can be
switched off, if required.
The instrument, designed for operations in
"heavy-duty" environments, is EMC-proof and equipped with a robust and
splash-proof housing. The GWL 10m is preferably used for room monitoring and
for the determination of restricted areas, where a given dose rate has been
achieved.
The GWL 10m is supplied together with a
recharger unit for recharging the built-in accumulator.
Optional accessories:
robust tripod
motion sensor triggering an acoustic alarm when a person approaches
towards a danger zone with increased radiation level
|
 |
|
Technical Data |
|
Type of radiation: |
gamma radiation / X-rays (DC installations) |
|
Detector: |
filtered GM-tube |
|
Measuring size: |
ambient dose equivalent rate H*(10) |
|
Alarm thresholds: |
7,5 µSv/h, 25 µSv/h, 1 mSv/h, 10 mSv/h |
|
Acoustic alarm: |
> 93 dB(A) measured in 30 cm distance,
can be switched off |
|
Energy range: |
40 keV - 1,3 MeV |
|
Temperature range: |
-30 °C up to +60 °C |
|
Power supply: |
accumulator
(operating time with fully charged accumulator
approx. 48 hours, without acoustic alarm) |
|
Housing: |
aluminium combined with high impact plastic
protection class
IP 65 |
|
Dimensions / Weight: |
(120 x 120 x 250) mm / approx. 2300 g |
|
The GammaSmart is a pocket-sized, very
robust, battery-operated dose rate alarm unit for the personal radiation
protection. It is designed for the detection of gamma radiation and X-rays,
indicating these with clear optical and significant acoustical pulse
repetition rate. An increasing dose rate leads to an increasing pulse
rate.
The splash-proof aluminium housing - equipped
with an optical battery control - ensures a shielding aginst electromagnetic
influence: the device is EMC-proof.
|
 |
|
Technical Data |
|
Type of radiation: |
gamma radiation / X-rays |
|
Detector: |
GM-tube |
|
Sensitivity: |
counting rate at 3 µSv/h approx. 1 count/min |
|
Acoustic Alarm: |
> 85 dB(A) measured in 30 cm distance |
|
Temperature range: |
-30 °C up to +60 °C |
|
Power supply: |
3 batteries type LR1 1,5V |
|
Housing: |
aluminium |
|
Dimensions / Weight: |
(130 x 50 x 20) mm / approx. 150 g |
| for personal radiation protection in explosion endangered
atmospheres
|
|
The dose rate alarm unit "GammaSmart V.Ex" is
a very robust and easy to handle pocket-sized alarm unit. It is accumulator
operated and designed for personal radiation protection.
It detects gamma radiation and X-rays,
indicating these with clear optical and acoustical single pulses. An
increasing dose rate leads to an increasing pulse rate.
The splash-proof aluminium housing (IP 54)
ensures a shielding against electromagnetic influence. An optical battery
control indicates the GammaSmart's readiness for use.
Recharge of the built-in accumulator requires
the recharger unit "GRAETZ 462L" (necessary accessories)
|
 |
|
Technical Data |
|
Type of radiation: |
gamma radiation / X-rays |
|
Detector: |
GM-tube |
|
Sensitivity: |
at 3 µSv/h approx. 1 count/min |
|
Ambient background radiation: |
approx. 1 count/2 min |
|
Acoustic alarm: |
> 85 dB(A) measured in 30 cm distance |
|
Temperature range: |
-20 °C up to +40 °C |
|
Power supply: |
lithium-polymer accumulator |
|
Operating time with fully charged accumulator: |
at ambient background radiation 2 months minimum |
|
Recharging time: |
approx. 1 hour |
|
Housing: |
aluminium |
|
Dimensions / Weight: |
(95 x 50 x 20) mm / approx. 150 g |
|
ATEX Approval No.: |
BVS 06 ATEX E 148 |
|
Marking: |
II 2G EEx ib IIB T4  |
|
Per
richiedere un preventivo per l'acquisto di
un misuratore di radioattivitą (dosimetro),
compila il form |
|