Sito
segnalato su: |
|
|
|
|
|
|
richiedi
un
preventivo
di
dosimetri
 |
|
|
with dose rate
indication and alarm functions
|
-
PTB-approved dosemeter for
measuring gamma and X-rays for the measuring size Hp
(personal dose equivalent)
-
detector: energy
compensated GM-tube
-
digital indication of
measured values on LC-display
-
dose indication range with
floating decimal point
-
dose rate indication upon
keystroke
-
high measuring accuracy
-
reliable and safe
measurement of radiation in front of the user's body (detection of a
solid angle of 180°)
-
especially shaped display
ensures optimum reading of measured values
-
switchable, acoustic
single-pulse indication
-
4 dose alarm thresholds
-
4 dose rate alarm
thresholds
-
menu-driven operator
guidance
-
optical interface
-
storage of dose value and
set parameters also during battery change
-
high reliability by
continuous self control and test function
-
small and handy metallized
housing made of high impact-proof plastic, easy to decontaminate
-
watertight up a a
submersion depth of 0,5 m acc. to protection class IP67
-
EMC-proof
-
power supply by 3 pcs.
1,5V Lady cells LR1
-
operating life approx. 1
year with one battery set at ambient background radiation
|
 |
|
Technical Data |
Measuring ranges:
- dose:
- dose rate:
- PTB-approved dose
1): |
0,1 µSv < Hp(10) < 10 Sv
0,1 µSv/h - 1,5 Sv/h
10 µSv/h < Hp(10) < 1 Sv/h |
|
Energy range: |
55 keV - 3 MeV |
|
Dose alarm thresholds |
4 preset values in the range of 1 µSv - 10 Sv |
|
Dose rate alarm thresholds: |
4 preset values in the range of 1 µSv/h - 1,5 Sv/h |
|
Temperature range: |
-20 °C up to +60 °C |
|
Dimensions / Weight: |
(136 x 40 x 17) mm / approx. 160 g |
|
PTB-Approval No.: |
23.52 / 04.01 |
|
German Fire Brigades Approval No.: |
DW/FW/IdF 040411 |
1) PTB-approved measuring range
for measurements specifically demanded by German authorities
|
with alarm function and
simultaneous display of dose and dose rate
|
-
for measuring gamma
radiation and X-rays
-
PTB-approved for the
measuring size Hp (photon dose equivalent)
-
detector: Geiger-Müller
tube
-
simple and clear operation
-
high measuring accuracy
-
simultaneous, digital
display of integrated dose rate
-
4 free programmable dose
alarm thresholds
-
4 free programmable dose
rate alarm thresholds
-
switchable, acoustic
single-pulse indication
-
storage of dose values and
set alarm thresholds also during battery change
-
high reliability by
continuous self monitoring and test functions
-
protection class IP 54
(splash-proof)
-
uses 2 pcs. standard 1,5V
Mignon cells IEC R6
-
EMC-proof
|
 |
|
Technical Data |
|
Dose measuring range: |
5 µSv - 10 Sv |
|
Dose indication range: |
1 µSv - 10 Sv |
|
Dose rate measuring range: |
30 µSv/h - 1 Sv/h |
|
Dose rate indication range: |
0,1 µSv/h - 1 Sv/h |
|
Energy range: |
48 keV - 2 MeV |
|
Dose alarm thresholds: |
4, free programmable (each independently acknowledgeable),
1 µSv - 10 Sv |
|
Dose rate alarm thresholds: |
4, free programmable (each independently acknowledgeable),
7,5 µSv/h - 1 Sv/h |
|
Temperature range: |
-20 °C up to +60 °C |
|
Battery life: |
approx. 1000 h (at background radiation -
bleeper function off) |
|
Dimensions / Weight: |
(120 x 65 x 22) mm (without Clip)
approx. 130 g (without batteries) |
|
PTB-Approval No.: |
23.03 / 96.05 |
|
Per
richiedere un preventivo per l'acquisto di
un misuratore di radioattivitą (dosimetro),
compila il form |
|