Extratech launched on the world market, WINDY, an automatic station for measuring anemometric parameters, built according to the standards of the WMO
(World Meteorology Organization), can be used with mains supply you with an automatic battery and photovoltaic panel system for installations open field.
Our system comes with a modular and expandable hardware architecture, so you can add different sensors and expand the monitoring system very easily and at very cheap prices.
The measured data are sent by integrated GPRS module on our web portal, where customers can query the system and display measurements in both tabular and graphical format.
The WS and WD professional sensors are designed for specific applications with low power consumption (<2 mA) making them ideal for monitoring kit powered by
solar panels.
On request, the system can be supplied with ACCREDIA certification.
WD - Wind direction sensor |
|

WD datasheet
 |
Measuring elements |
wind vane, aluminum |
Measuring principle |
Magnetic |
Measuring range / Accuracy |
0-360° / < 2° |
Resolution / Starting value |
1° / 0,4 m/s |
Supply voltage |
4-15 Vdc |
Current consumption |
< 2 mA
(low power) |
Strongest wind impact velocity |
80 m/s |
Dimensions |
wind vane L=230mm H=256mm |
Weight |
approx 0,95 Kg |
Temperature measuring range |
-40..+70°C under non-icing environmental conditions |
Housing |
sea water
resistant aluminium, IP65, for bores with
f=30mm
at max, 10 mm material thickness, include plug connector |
|
|
|
WS - Sensore per la velocitŕ del vento |
|

WS datasheet
 |
Measuring elements |
3-armed cup rotor, aluminum |
Measuring principle |
Magnetic |
Measuring range / Accuracy |
0,5 - 55 m/s / <0,5 m/s |
Resolution / Starting value |
<0,1 m/s / 0,4 m/s |
Supply voltage |
4-15 Vdc |
Current consumption |
< 2 mA
(low power) |
Strongest wind impact velocity |
80 m/s |
Dimensions |
cup rotor
f=108mm
H=192mm |
Weight |
approx 0,90 Kg |
Temperature measuring range |
-40..+70°C under non-icing environmental conditions |
Housing |
sea water resistant aluminium, IP65, for bores with
f=30mm at max, 10 mm material thickness, include plug connector |
|
|
|
 |
|